Presence
ECO IR 360 Presence Detector
- Passive infra-red sensor for ceiling installation
- Presence detector for large-area applications
in classrooms, offices and public areas - Square detection range 360°
- Automatic control of lighting and HVAC
- “Genuine daylight measurement”
- Light output
- Lighting control with light threshold value and self-learning run-on time
- Choice of fully or semi-automatic operation
- Presence output for HVAC control with run-on time
- The switching behaviour of the presence detector is controlled by presence and light
- The lighting switches on with darkness and presence and off with sufficient light or absence
- Fully or semi-automatic: In “Fully automatic” mode the light switches on and off automatically according to presence and light. In “Semi-automatic” mode it must be switched on manually and switches off automatically
- The presence detector has “Genuine light measurement” and is only suitable for switching fluorescent lamps (FL/PL)
- The ECO-IR180EIB-AC detects moving bodies in a radius of approx. 8 m. Seated persons can be reliably detected in an area of 8 m x 4 m. The recommended installation height is 2.2 m
- Presence output for HVAC control : Switching behaviour is only controlled by presence
- Master/slave parallel switching: Several detectors can be connected with each other to increase the detection area
- The master controls lighting and HVAC. All other detectors merely provide presence information as slaves
- Master or slave operating mode is selected via configuration
- Master/master parallel switching: Several detectors can be connected with each other to control several lighting groups
- Every master controls its lighting group according to its own light measurements. Presence is detected by all the detectors
- Test operating mode checks the detection range and configuration
- The parameters are set by ETS or potentiometer
Specification
| Genuine daylight measurement | Approx. 100–1600 lux can be deactivated, approx. 25–200 lux (extended) |
|---|---|
| Light run-on time | 30 s-20 min |
| Presence run-on time | 30 s-60 min |
| Mounting plate | 70 × 70 mm |
| Connection | Bus terminal |
| Size of flush-mounted socket | Socket Ø 55 mm (NIS, PMI) |
| Ambient temperature | +0 °C… +45 °C |
| Protection rating | IP 40 |
| Detection range | 360° horizontal, 120° vertical |
| Recommended installation height | 2.0 m–3.5 m |
| Max. range | Max. 8 × 8 m at a height of 2.5 m. max. 10 × 10 m at a height of 3.5 m |
NOTE: Timeguard has a policy of continuous product development and reserve the right to alter specifications at any time. Therefore, unavoidable differences between product and website specifications may occur, for which liability cannot be accepted by Timeguard.