Thermolay UFH Controllers

RCD10WL RCD White Fused Connection Unit

RCD Fused Connection Unit gives additional protection against electric shocks and fire risk. The unit will remain latched if the power supply is tripped and is recommended for all underfloor heating installations up to 13A loading.

  • Extra fast action – trips out within 40 milliseconds (BS7288).
  • Automatically disconnects both Live and Neutral connections leaving Earth connection intact.
  • Latching for continuous operation after supply interruption.
  • Complies with BS7288.
  • Part No. RCD10WL

« Back to product section

Specification

Type Non-Latching
Operating Voltage 230V AC
Current Rating 13A
Rated Trip Current 30mA
Trip Speed BS 7288 – 40ms
Contact Break Double Pole
Continues to Protect With Lost neutral & pulsating DC earth fault
Cable Capacity Up to 10.5mm²
Conforms To BS7288
Dimensions (mm) Height 85, Width 85, Depth 40
Min Box Depth 25mm

NOTE: Timeguard has a policy of continuous product development and reserve the right to alter specifications at any time. Therefore, unavoidable differences between product and website specifications may occur, for which liability cannot be accepted by Timeguard.