Theben DIN Rail Timeswitches

LU113 Twilight Switch (4 Module - Dual Range)

The LU113 has all the features and benefits of the LU110 but is a 2 channel 10(6)A switch with 2 brightness ranges, 2-150 Lux and 150-7500 Lux

  • Surface Mount Kit Part No. 907.0.049
  • Surface Mount Light Sensor (spare) Part No. 907.0.031
  • Part No. LU113

www.theben.de

Specification

Timer Mode Dusk/Dawn
Setting Type Adjusting Screw
Brightness Range LUX 2 – 7500
Adjustment Brightness Range 2 Ranges
Switching Delay ON/OFF 40/40 sec
Voltage Free Contacts Single Pole Changeover
Operating Voltage 230V AC
Switch Rating 230V AC Resistive 10A, Inductive 6A
Operating Temperature -10 to 50°C
Operating Temperature Sensor -40 to 70°C
Conforms to Directives 73/23/EEC, 89/336/EEC
Dimensions Width 72, Height 86, Depth 65.5

Lamp Loads: LU113 (1000W filament lamps, 200W fluorescents. Not suitable for low energy or discharge lighting).